Alinity c

Clinical chemistry

Maximizes testing throughput with high-quality assays to deliver efficient and accurate results for greater productivity.

  • Method: Photometric, Potentiometric
  • Sample Type*: Serum, plasma, urine, cerebrospinal fluid, hemolysate, whole blood
  • Sample Capacity: 150
  • Reagent Capacity: Up to 70
  • Maximum Throughput: Up to 1,350 tests/hour

*Assay dependent.

Learn more about Alinity c

Alinity i

Immunoassay

Utilizes proven CHEMIFLEX chemiluminescent detection technology with an assay design free from biotin interference to provide greater confidence in results.1,2

  • Method: Chemiluminescence
  • Sample Type*: Serum, plasma, whole blood, urine
  • Sample Capacity: 150
  • Reagent Capacity: Up to 47
  • Maximum Throughput: Up to 200 tests/hour

Learn more about Alinity i

Alinity ci-series

Integrated clinical chemistry and immunoassay

Offers powerful integration across clinical chemistry and immunoassay. These systems can easily scale, combining up to four modules in multiple configurations to meet your laboratory’s diagnostics needs and maximize its operational efficiency.

Click below for additional information on the Alinity ci-series.

  • Method: Photometric, Potentiometric,Chemiluminescence
  • Sample Type*: Serum, plasma, urine, cerebrospinal fluid, hemolysate, whole blood
  • Sample Capacity: 300
  • Reagent Positions: Up to 117
  • Maximum Throughput: Up to 1,550 test/hour

*Assay dependent

Our broad menu of differentiated assays delivers consistent, commutable results across systems for clinical decision-making and patient outcomes. Alinity ci-series assays are harmonized to CLSI guidelines, ensuring clear performance parameter definitions, and leverage the same technology that Abbott developed for its ARCHITECT legacy systems, making for commutable results across platforms.

Click the "Learn More" button below for additional information on the Alinity ci-series.

Alinity ci-series | Core Laboratory at Abbott (6)

Alinity ci-series | Core Laboratory at Abbott (7)

Alinity ci-series | Core Laboratory at Abbott (8)

Uniformity

Standardize operations across the lab and network,and optimize limited resources.

Common design and user experience

Simple, intuitive interactions plus common software and icons enable staff to navigate easily from one system to the next.

Common reagent and solution packaging

Reagents and solutions packaged in distinct color-coded and error-proof bottles make loading on the fly fast and effortless.

Common loading process

A consistent, easy process across systems supports fast and effcient sample loading.

Flexibility

Adapt to day-today and long-term unpredictability of changing lab volumes.

Scalable Systems

Easily add up to four modules in varying combinations, all controlled by a single system control module.

Multiple Track Connectivity Options

Customize the design of the track and how systems connect, with parallel and perpendicular connections.

Open Automation and Informatics

Open automation and informatics enables connections to Alinity, other Abbott or most common third party systems to the track across multiple departments.

Operational Productivity

Address limited space and increasing demand with increased throughput and capacity.

Increased Load-up Capacity in a compact cootprint for Maximum Throughput

A stacked reagent and sample carousel design allows more reagents and samples on board for more tests per square meter.

Streamlined Footprint of Reagents and Sample Racks and Continuous Loading for Uninterrupted Testing

Reagent cartridges and sample racks have a streamlined footprint for easy loading. Consumables can be loaded continuously without interruption to tests in process.

Onboard Calibrators and Controls

Calibrators and controls can be programmed to automatically run at chosen intervals, allowing operators to stay focused on other key tasks.

Confidence

Provide consistent high-quality service in today's high-pressure environment.

Error-Proof Design Elements

Error-proof design elements and color coding ensure reagents and bulk solutions are loaded correctly, avoiding potential repeat testing and downtime.

Quality Assays with Proven Technology

A broad menu of quality assays utilizing some of the same proven technologies available in our legacy systems and offering commutable results across platforms.

Always On Active Sense Technologies

Always On Services can proactively monitor Alinity instruments 24/7, driving consistent uptime and turnaround time.

Connect with a representative fromAbbott to learn more about how the Alinity ci-series can help maximize your laboratory's potential.

Request more info

Alinity ci-series | Core Laboratory at Abbott (9)

Alinity ci-series | Core Laboratory at Abbott (10)

Alinity ci-series | Core Laboratory at Abbott (11)

Explore

End to End Solutions

Learn how Abbott’s End to End Solution unlocks synergistic value, helping your lab achieve and sustain excellence.

Visit End to End solutions

Knowledge Center

Find the latest information in laboratory science, therapeutic areas and Abbott innovation.

Visit the Knowledge Center

Leverage The Lab

Learn how Abbott's strategic transformation plan provided laboratories insights and health system performance improvements.

Visit Leverage the Lab

References
  1. Li D, Ferguson A, Cervinski MA, Lynch KL, Kyle PB. AACC guidance document on biotin interference in laboratory tests. [Epub] J Appl Lab Med January 13, 2020, as doi:10.1373/10.1093/jalm/jfz010.
  2. M. Hauptman, J. Jaraskweski, R. Schneider. Evaluation of Biotin Interference on the Abbott ARCHITECT Assays. July - August 2017.
Alinity ci-series | Core Laboratory at Abbott (2024)

FAQs

What is Abbott Alinity used for? ›

Purpose-built for blood and plasma screening, this transformational innovation empowers blood and plasma services to simultaneously protect the global supply of safe blood and plasma products and achieve greater operational efficiency.

What is the Abbott Alinity immunoassay PSA test? ›

The Abbott assay is approved as an aid in the detection of prostate cancer when used in conjunction with digital rectal exam (DRE) in men 50 years or older, or as an adjunctive test to aid in the management of prostate cancer patients. Elevated PSA concentrations can only suggest the presence of prostate cancer.

What is alinity ci? ›

The Alinity systems for clinical chemistry and immunoassay testing will reduce the size of Abbott's current diagnostics systems by half and will help laboratory professionals: Run more tests in less time. Increase testing productivity in a smaller instrument footprint. Scalable systems with open connectivity.

What is the principle of Alinity I test? ›

The Alinity i system (Abbott Laboratories, IL, USA), a recently launched automated immunoassay analyzer utilizes chemiluminescent microparticle immunoassay (CMIA) principle, by using anti-analyte coated paramagnetic microparticles and anti-analyte acridinium-labeled conjugates.

How does Abbott Istat work? ›

The i-STAT is a cartridge-based analyser with all the analytical requirements for the performance of a test contained within an individual cartridge. The test sample and reagents never enter the 'analyser' which transforms electrical signals from the test cartridge into human-readable results.

What is a high score for a PSA test? ›

Decoding a PSA Test

For men in their 40s and 50s: A PSA score greater than 2.5 ng/ml is considered abnormal. The median PSA for this age range is 0.6 to 0.7 ng/ml. For men in their 60s: A PSA score greater than 4.0 ng/ml is considered abnormal. The normal range is between 1.0 and 1.5 ng/ml.

What is the most accurate test for PSA? ›

Biopsy. If your doctor finds an abnormality during a DRE or MRI, or if PSA testing detects a raised PSA level, you may need a biopsy. A prostate biopsy is one of the most accurate ways to diagnose prostate cancer.

What is the new test instead of PSA? ›

New Prostate Cancer Blood Test

If you have an abnormal PSA score, your doctor may recommend another newer test that gives a better sense of your prostate cancer risk . The prostate health index (PHI) is one such test that is a more accurate blood test and measures your risk for having prostate cancer.

What is the cost of Abbott biochemistry analyzer? ›

Semi Automatic Abbott Biochemistry Analyzer at Rs 220000/1 piece in Bengaluru | ID: 21897529230.

Why was Alinity cancelled? ›

She stated that the ban was a consequence of "twerking" on stream, violating Twitch's guidelines on suggestive and sexual content.

What is Chemiflex technology? ›

CHEMIFLEX TECHNOLOGY5

ARCHITECT utilizes a unique combination of refined chemiluminescence detection technology with flexible assay protocols. CHEMIFLEX, when combined with optimized assay design, provides enhanced assay performance. CHEMIFLEX delivers: * Excellent sensitivity. * Excellent specificity.

What is Alinity blood test? ›

Purpose-built for blood and plasma screening.

Alinity s allows the laboratory staff to process more samples with less effort, greater consistency and control. This leads to more efficient resource utilization and a more productive blood and plasma screening process.

What is the Abbott machine principle? ›

Abbott Architect Method Principle . The assay is an automated, two step immunoassay to detect qualitatively IgG antibodies to SARS-Cov-2 in plasma and serum samples using a chemiluminescent microparticle immunoassay (CMIS).

What is the principle of Abbott CMIA? ›

2.2.

The Abbott CMIA based on paramagnetic microparticle chemiluminescent technology. The reaction principle is as follows: Microparticle is coated with three recombinant antigens (Ag) (TpN15, TpN17, TpN47) to band IgG and IgM antibodies specific for TP.

What does Abbott COVID test mean? ›

The nasal swab is then inserted into the test card. In 15 minutes, a line will indicate whether the person has tested positive or negative for COVID-19 (one line indicates negative, two lines indicate positive).

What is the use of INJ Abbott? ›

Abbott Sodium Chloride Injection consists of purified salt solution. It is used for short term fluid replacement. Thus, it treats hypovolemia that can result due to any dehydration, or injury. It helps to restore the salt and electrolyte levels in the body.

References

Top Articles
Latest Posts
Article information

Author: Rueben Jacobs

Last Updated:

Views: 5539

Rating: 4.7 / 5 (77 voted)

Reviews: 92% of readers found this page helpful

Author information

Name: Rueben Jacobs

Birthday: 1999-03-14

Address: 951 Caterina Walk, Schambergerside, CA 67667-0896

Phone: +6881806848632

Job: Internal Education Planner

Hobby: Candle making, Cabaret, Poi, Gambling, Rock climbing, Wood carving, Computer programming

Introduction: My name is Rueben Jacobs, I am a cooperative, beautiful, kind, comfortable, glamorous, open, magnificent person who loves writing and wants to share my knowledge and understanding with you.